TissuePro is the first soft non-reflective sleeve for the intraoral end of the Minnesota retractor to minimize trauma when retracting tissue. It enhances blood supply for faster healing and reduces slippage on bone. It is autoclavable for up to 30 cycles. Fits securely and safely to the Minnesota retractor and is easy to remove after the procedure. (12 instruments per bag).
TissuePro™ Sleeves are intended to be used with a Minnesota retractor to retract soft tissues such as the cheeks, lips, and tongue during dental procedures, while minimizing soft-tissue trauma and operator fatigue. The sleeve provides a protective, atraumatic barrier and a non-reflective surface to improve intraoral visibility.
Instructions for Use
-
Before First Use (Autoclavable Versions Only):
- Remove all packaging materials.
- Wash thoroughly with mild, neutral pH detergent and rinse with deionized or distilled water.
- Autoclave prior to first clinical use according to the validated sterilization parameters.
-
Installation and Use:
- Select the appropriate sleeve model (intraoral, external, or all-in-one).
- Slide the sleeve gently over the Minnesota retractor until it is fully seated and secure.
- Ensure the sleeve does not slip during use and is properly positioned for optimal comfort and visibility.
- Retract soft tissues as required during the procedure.
- Verify that the sleeve remains in position throughout use.
Instructions for Reprocessing (Autoclavable Sleeves Only)
-
Cleaning
- Immediately after use, remove the sleeve from the retractor.
- Rinse under cool running water to remove debris.
- Place the device in an ultrasonic cleaner with enzymatic detergent for 15 minutes.
- Using a soft-bristled brush and neutral pH detergent, scrub all external surfaces.
- Clean both the interior and exterior using a long-handled soft brush.
- Rinse thoroughly with deionized or distilled water.
-
Drying
- Air dry the sleeve completely before sterilization.
- Important: Incomplete drying may compromise sterilization or damage the sleeve.
-
Sterilization
- Method: Steam sterilization (autoclave). Cycle Options:
- 134 °C (273 °F) for 5 minutes, or
- 121 °C (250 °F) for 20 minutes.
- Do not exceed 136 °C (277 °F). Use only clean, distilled steam in accordance with EN 285 standards.
- Allow the full drying cycle to complete before removing the sleeve.
- Do not use dry-heat sterilization.
- Method: Steam sterilization (autoclave). Cycle Options:
Product Life Autoclavable Sleeves:
- Maximum of 30 autoclave cycles.
- Replace immediately if discoloration, brittleness, cracking, or other damage is observed.
TissuePro™ Soft Intraoral (Item Number: 117010): 12 Sleeves per bag (Autoclavable)
Q: Is TissuePro contain animal or human cell?
A: TissuePro™ Sleeves do not contain any animal or human cells, tissues, or derivatives thereof; cells, tissues, or derivatives of microbial or recombinant origin; or irradiating components, whether ionizing or non-ionizing. TissuePro™ Sleeves do not incorporate any materials that are endocrine-disrupting, carcinogenic, mutagenic, or toxic to reproduction, nor any materials that could cause sensitization or allergic reactions in the patient or user.
Q: Does TissuePro Contain latex?
A: TissuePro™ Sleeves do not contain latex.